EURODACH 

Breather membrane designed for unventilated or boarded 

construction of pitched roofs

 

Function

 

The materials as sub-roof vapour permeable hydroinsulating material protects sub-roof thermal insulation as well as sub-roof space against moisture generated by rain and snow, and against dust and soot and adverse wind conditions, too. At the same time due to its high vapour permeability is allowed to vent water vapours from inner space of the building.

Use EURODACH 135 and 150 breather membranes for all pitched roof designs (ventilated, unventilated, unboarded) as well as for assembled vertical claddings and also as wind barriers.

Use EURODACH 95 and 115 breather membranes for pitched roof designs (ventilated, unventilated, but not boarded) as well as for assembled vertical claddings and also as wind barriers.

 

Specifications

 

This is the special multilayer material consisting of outer spunbonded polypropylene layers ensuring the strength and a central layer ensuring the hydroinsulation ability. Since the layers are made from non-woven textiles this material provides high vapour permeability.

 

Technical data

 
  Unit Types Standard
Material 100% polypropylene
Weight g/m² 95 115 135 150 EN 1849-2
Width cm 150 150 150 150 EN 1848-2
Tensil Force Break N/5 cm 180/130 200/155 230/180 210/200 EN 12311-1
Water vapour permeability g/m²/d >1200 >1200 >1200 >1200 DIN 52615
Water resistance cm >100 >200 >200 >200 EN 20811
 Sd value m 0,02 0,02 0,02 0,04
Fire resistance    B2 B2 B2 B2 DIN 4102
UV stability months 4 4 4 4
Packing 1,5 x 50 bm = 75 m²

 

 

Sales manager: ing Jánský

 

 

 

top